If a CBC and/or an antibody screening test is ordered with this test, please submit a separate 4 mL specimen for each test.
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
Lavender-top (EDTA) tube
Specimens should be tested as soon as possible. Samples that cannot be tested immediately should be stored at 2°C to 8°C. Do not freeze red cells.
Gross hemolysis; bacterial or other contamination
Determination of ABO blood group and Rh type for transfusion candidates. Group and typing of expectant mothers and newborns may indicate potential for ABO hemolytic disease of the fetus/newborn. Rh typing is used to determine Rh immune globulin candidacy for prenatal and postpartum patients.
Abnormal plasma proteins, cold autoagglutinins, positive direct antiglobulin test, and, in some cases, bacteremia may interfere with test interpretation. Variable testing results may be observed with partial antigens, which are rare variants of the D antigen.
Fung MK, Grossman JB, Hillyer CD, Westoff CM, eds. AABB Technical Manual. 18th ed. Bethesda, Md: American Association of Blood Banks;2014.
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
006049 | ABO Grouping and Rho(D) Typing | 34530-6 | 006056 | ABO Grouping | 883-9 | |
006049 | ABO Grouping and Rho(D) Typing | 34530-6 | 006064 | Rh Factor | 10331-7 |
Reflex Table for ABO Grouping | ||||||
---|---|---|---|---|---|---|
Order Code | Order Name | Result Code | Result Name | UofM | Result LOINC | |
Reflex 1 | 114067 | ABO Grouping | 006051 | ABO Grouping | 883-9 |
Reflex Table for Rh Factor | ||||||
---|---|---|---|---|---|---|
Order Code | Order Name | Result Code | Result Name | UofM | Result LOINC | |
Reflex 1 | 114066 | Rh Factor | 006052 | Rh Factor | 10331-7 |
Please login to order a test
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf
© 2024 Laboratory Corporation of America® Holdings. All Rights Reserved | Do Not Sell/Share My Personal Information